Skip to main content

Armed Forces: Protective Clothing

Question for Ministry of Defence

UIN 37772, tabled on 12 March 2025

To ask the Secretary of State for Defence, pursuant to the Answer of 11 March 2025 to Question 36209, what the difference in attenuation across the frequency bands is between the (a) Peltor ComTac XP/XPI and (b) General Service Peltor Ear Muff.

Answered on

20 March 2025

The performance of the ComTac XP/XPI and the General Service Peltor Ear Muff is as follows:

ComTac XP/XPI

Frequency (Hz)

125

250

500

1000

2000

4000

8000

Mean attenuation (dB)

11.5

17.9

27.8

30.0

32.1

36.2

40.3

Std deviation (dB)

2.5

2.7

1.8

2.3

3.0

2.0

3.1

Assumed Protection Value (dB)

9.0

15.3

25.9

27.7

29.1

34.2

37.2

SNR=28 db H=31 db M=25 db L=16 db

General Service Peltor Ear Muff

Frequency (Hz)

125

250

500

1000

2000

4000

8000

Mean attenuation (dB)

16.2

17.0

26.4

33.5

37.1

39.1

34.3

Std deviation (dB)

4.1

2.7

2.9

4.6

2.8

3.6

4.7

Assumed Protection Value (dB)

12.1

14.3

23.5

28.9

34.3

35.5

29.6

SNR=28 db H=33 db M=25 db L=18 db